NEWSLETTER VCCI新旧版本差异-后续
Ladies and 乡亲们!对,还是我-美貌与智慧并存的芭拉小编在此恭候各位!今天来为乡亲们讲讲VCCI详细测试信息。
VCCI各测试项的限值
1.电源端口的传导骚扰:
A类限值
Frequency range MHZ |
Quasi-peak dB(μV) |
Average dB(μV) |
0.15-0.5 0.5-30 |
79 73 |
66 60 |
B类限值
Frequency range MHZ |
Quasi-peak dB(μV) |
Average dB(μV) |
0.15-0.5 0.5-5 5-30 |
66-56 56 60 |
56-46 46 50 |
2.电信端口的传导骚扰:
A类限值
Frequency range MHZ |
Voltage limits dB(μV) |
Current limits dB(μA) |
||
0.15 to 0.5 0.5 to 30 |
97 to 87 87 |
84 to 74 74 |
53 to 43 43 |
40 to 30 30 |
B类限值
Frequency range MHZ |
Voltage limits dB(μV) |
Current limits dB(μA) |
||
0.15 to 0.5 0.5 to 30 |
84 to 74 74 |
74 to 64 64 |
40 to 30 30 |
30 to 20 20 |
3.辐射骚扰
A类:
1GHZ以下(测试距离为10m,当测试距离为3m时,限值加10db)
Frequency range MHZ |
Quasi-peak dB(μV/m) |
30-230 230-1000 |
40 47 |
1GHZ以上(测试距离为3m)
Frequency GHZ |
Average limit dB(μV/m) |
Peak limit dB(μV/m) |
1-3 3-6 |
56 60 |
76 80 |
B类:
1GHZ以下(测试距离为10m,当测试距离为3m时,限值加10db)
Frequency range MHZ |
Quasi-peak dB(μV/m) |
30-230 230-1000 |
30 37 |
1GHZ以上(测试距离为3m)
Frequency GHZ |
Average limit dB(μV/m) |
Peak limit dB(μV/m) |
1-3 3-6 |
50 54 |
70 74 |
辐射骚扰测量频率的选择:
1. 如果EUT的内部最高频率低于108MHZ,测试只需要到1GHZ。
2. 如果EUT的内部最高频率在108MHZ和500MHZ之间,测试只需要到2GHZ。
3. 如果EUT的内部最高频率在500MHZ和1GHZ之间,测试只需要到5GHZ。
4. 如果EUT的内部最高频率高于1GHZ,测试需要到最高频率的5倍或者6GHZ。
对EUT布置的一般要求:
1. EUT的配置,布置和运行应和典型的应用情况一致,应将接口电缆,负载,或装置与EUT中的每一种类的接口端口中的至少一个端口相连;
2. 如果同一类有多个接口,如果增加线缆,不明显影响发射电平的大小,变化小于2dB,则同一类接口接一个端口即可;
3. 对于通常有多个模块的设备应按典型应用中的模块数目和组合情况进行实验,增加相同类型的电路板或插卡的数量,变化小于2dB,选择模块的数量和类型的理由应在报告中注明。
来源:BALUN原创 作者:李鹏 责任编辑:芭拉小编
欢迎转载,请注明出处